KPM51 is a multifunction single phase smart power meters, it integrates all power parameter measurements, modbus communications, remote control, etc. It is multifunctional and cost-effective, can be independently used in different occasions power measurement and display, helping customers save investment and use of space, it has been widely used in various industries.
Function
Specification
Download
Function
- Single phase smart power meter
- Full electrical parameter measurement:
- UL-L, UL-N, I, F, PF;
- P, Q, S, bidirectional energy, etc.
- High accuracy:
- U Class 0.2;I Class 0.2;
- P Class 0.5S; Active energy Class 0.5S
- Record function:
- Monthly average power factor and power data for the last three months
- Meter working time, load time statics
- Communication: RS485/Modbus-RTU
- Optional function: 2 digital inputs;2 digital outputs
- Optional function: PT100 temperature monitoring;4-20mA analog output
Specification
Working power source |
Operating Voltage |
AC 85-265V/ DC 80-300V |
|
Rated power consumption |
< 3VA |
Input voltage |
Rated voltage |
110/220V |
|
Overvoltage capability |
1.2 times rated voltage allowed, continuous work; 2 times the rated voltage allowed 10S |
|
Rated power consumption |
<0.5VA(per phase) |
|
Measurement range |
5~260VAC |
Input current |
Rated current |
Default 5A, input range 1-6A; optional 1A, input range 1-1.2A |
|
Overload capacity |
1.2 times rated current allowed, continuous work; 20 times the rated current allowed 1S |
|
Rated power consumption |
<0.75VA/phase(5A); <0.25VA/phase (1A) |
|
Measurement range |
5A:0~6A; 1A:0~1.2A |
Measurement accuracy |
Voltage |
±0.2%(0.01V) |
|
Current |
±0.2%(0.01A) |
|
Active power |
±0.5%(0.01W) |
|
Reactive power |
±2.0%(0.01var) |
|
Power factor |
±0.5%(0.001) |
|
Frequency |
±0.02 (0.01Hz) |
|
Active energy |
±0.5%(0.1kwh) |
|
Reactive energy |
±2.0%(0.1kvarh) |
|
Temperature |
±1℃(1℃) |
Communication |
communication port |
RS485,Photoelectric isolation interface |
|
Communication protocol |
Modbus-RTU, 1200-38400BPS |
DI & DO |
Switch value input |
2-way passive main line contact DI input, internal supply DC24V power supply |
|
Relay output |
2-Way DO output, contact capacity 250VAC / 5A, 30VDC / 5A |
|
Analog output |
Output range 4-20mA, overload 1.2 times |
|
Temperature input |
Temperature range 0-100℃ |
Working environment |
Operating temperature |
-25℃ ~ +70℃ |
|
Storage temperature |
-30℃ ~ +75℃ |
|
Relative humidity |
5% ~ 95% No condensation |
|
Altitude |
Not more than 4000m |
Electrical insulation |
Dielectric strength |
Power frequency voltage AC 2kV, working time 1 min |
|
Insulation resistance |
>50MΩ |
|
Impact voltage |
5kV (Peak),1.2/50us |
Electromagnetic Compatibility |
Electrostatic discharge immunity |
IEC61000-4-3, level 4 |
|
Fast pulse group immunity |
IEC61000-4-4, level 4 |
|
Surge immunity |
IEC61000-4-5, level 4 |
|
Power frequency magnetic field immunity |
IEC61000-4-8, level 4 |